The following analysis is based on an industrial operating profile with a 100% operating duty cycle. The MTBF hours are calendar hours.

External Ambient Temperature: +25ºC

Operating Environment: Ground Fixed

MTBF (Calculated): 939,856 Hours

Unit Failure Rate at 12 months:  0.93%

External Ambient Temperature: +85ºC

Operating Environment: Ground Fixed

MTBF (Calculated): 158,727 Hours

Unit Failure Rate at 12 months:  5.37%

External Ambient Temperature: +25ºC

Operating Environment: Ground Mobile

MTBF (Calculated): 710,065 Hours

Unit Failure Rate at 12 months:  1.23%

External Ambient Temperature: +85ºC

Operating Environment: Ground Mobile

MTBF (Calculated): 138,023 Hours

Unit Failure Rate at 12 months:  6.15%